Medindia
Take charge of your health! Register
Medindia » Health In Focus

Fluorescent Urine Test Can Detect Organ Transplant Rejection: Here's How

by Dr. Kaushik Bharati on February 22, 2019 at 6:21 PM
Listen to this News

Highlights:

Fluorescing urine is capable of detecting organ transplant rejection, suggests a new study. This has been made possible by a new urine test that uses nanoparticle sensors. This test can detect organ rejection much earlier than is possible by conventional needle biopsy.


Rejection occurs due to the attack of immune cells on the transplanted organ. As soon as rejection starts to occur, an enzyme called �Granzyme B' present in T-cells of the immune system is released into the blood. The nanoparticle sensors detect this enzyme and send out fluorescent signals that filter through the kidneys and pass out in the urine, which exhibits fluorescence.

‘Fluorescing urine can detect transplant rejection early. Nanoparticle sensors become activated by Granzyme B released by T-cells due to rejection and hence emit fluorescent signals in the urine.’

Scientists at the Georgia Tech School of Engineering and Emory University, USA have developed these novel nanoparticle-based sensors using biocompatible materials. This means that it will be easier for the new technology to be approved for human clinical trials in the future, without facing any ethical issues.

The study, published in the journal Nature Biomedical Engineering, was jointly led by Dr. Gabe A. Kwong, PhD and Dr. Andrew B. Adams, MD, PhD.

Dr. Kwong is an Assistant Professor in the Wallace H. Coulter Department of Biomedical Engineering at Georgia Tech School of Engineering and Emory University School of Medicine, USA.

Dr. Adams is an Associate Professor of Surgery in the Division of Transplantation, Department of Surgery at Emory University School of Medicine, USA.

Drawbacks of Biopsy - The Gold Standard for Detecting Organ Rejection

Biopsy, in spite of being the Gold Standard for detection, still has certain drawbacks, which include the following:

Advantages of the New Technology

With reference to the new test, Adams says: "This is sensitive enough to possibly detect budding rejection before you see significant injury to the transplanted organ and that could help clinicians treat early to prevent damage." He adds: "Right now, most tests are aimed at organ dysfunction, and sometimes they don't signal there is a problem until organ function is below 50 percent."

Structure of the Nanoparticle Sensors

The nanoparticles are assembled by using iron oxide as its spherical core. This is covered by two layers, made up of dextran (glucose polymers) and polyethylene glycol (PEG), which is a component of laxatives. This ensures that the nanoparticles are not excreted out of the body too fast. On the surface of the spherical nanoparticles, are attached amino acid chains that look much like "bristles". Fluorescent markers consisting of "reporter" molecules are attached to the tips of these bristles. These molecules emit fluorescent signals as soon as organ transplant rejection starts to occur, making the test highly sensitive.

Mechanism of Action of the Nanoparticle Sensors

As soon as rejection sets-in, the granzyme B enzyme degrades the amino acid chains on the organ's surface layer of cells, thereby triggering a cascade that eventually results in cell death by a process known as apoptosis or programmed cell death.

With reference to the action of granzyme B on the nanoparticle sensors, Kwong says: "The nanoparticles' bristles mimic granzyme's amino acid targets in the cells, so the enzyme cuts the bristles on the nanoparticle at the same time." He adds: "That releases the reporter molecules, which are so small that they easily make it through the kidney's filtration and go into the urine."

The researchers applied skin grafts on mice and were able to obtain a clear signal from the nanoparticle sensors. The urine of the mice glowed with a fluorescent tinge, which could be visualized in their bladders by near-infrared imaging.

Future Plans

Future plans include improvement of the nanoparticle sensors so that they can detect other major causes of transplant rejection such as antibody-mediated attack on the transplanted organ. These types of antibodies, known as "autoantibodies", are particularly harmful as they fail to distinguish between "self" and "non-self" - one of the cardinal features of the immune system - and therefore attack the transplanted organ.

Other applications for the new technology are also planned, as indicated by Adams. He says: "This method could be adapted to tease out multiple problems like rejection, infection or injury to the transplanted organ." He adds: "The treatments for all of those are different, so we could select the proper treatment or combination of treatments and also use the test to measure how effective treatment is."

Funding Source

The study was funded by the Burroughs Wellcome Fund, the National Institutes of Health and its National Institute of Allergy and Infectious Diseases, and the National Science Foundation, USA.

Reference:
  1. Non-invasive Early Detection of Acute Transplant Rejection via Nanosensors of Granzyme B Activity - (https:doi.org/10.1038/s41551-019-0358-7)


Source: Medindia

Cite this Article

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Dr. Kaushik Bharati. (2019, February 22). Fluorescent Urine Test Can Detect Organ Transplant Rejection: Here's How. Medindia. Retrieved on Nov 18, 2024 from https://www.medindia.net/news/healthinfocus/fluorescent-urine-test-can-detect-organ-transplant-rejection-heres-how-186080-1.htm.

  • MLA

    Dr. Kaushik Bharati. "Fluorescent Urine Test Can Detect Organ Transplant Rejection: Here's How". Medindia. Nov 18, 2024. <https://www.medindia.net/news/healthinfocus/fluorescent-urine-test-can-detect-organ-transplant-rejection-heres-how-186080-1.htm>.

  • Chicago

    Dr. Kaushik Bharati. "Fluorescent Urine Test Can Detect Organ Transplant Rejection: Here's How". Medindia. https://www.medindia.net/news/healthinfocus/fluorescent-urine-test-can-detect-organ-transplant-rejection-heres-how-186080-1.htm. (accessed Nov 18, 2024).

  • Harvard

    Dr. Kaushik Bharati. 2019. Fluorescent Urine Test Can Detect Organ Transplant Rejection: Here's How. Medindia, viewed Nov 18, 2024, https://www.medindia.net/news/healthinfocus/fluorescent-urine-test-can-detect-organ-transplant-rejection-heres-how-186080-1.htm.

View Non AMP Site | Back to top ↑