Infant Jarvik 2015 is an implantable axial-flow ventricular assist device that offers improved hemolysis profile, a usual challenge in small pumps.
For children with severe heart failure, the only available means of life support are ventricular assist devices (VADs) placed outside the body. The National Heart, Lung and Blood Institute, investigators have now developed a miniaturized implantableVAD for small children. The number of children with severe heart failure is increasing. Over the last decade, ventricular assist devices (VADs) have become the standard of care in the management of severe heart failure.
‘The Infant Jarvik 2015 offers up to 3.0 liters per minute flow rate, which is approximately double the flow its predecessor can provide.’
In adults, implantable VADs (i.e. pumps placed within the chest) are used exclusively, due in part to favorable risk profiles and, more importantly, the opportunity for home discharge and outpatient management. By contrast, no implantable VADs designed specifically for small children (approximately 5 to 20 kg) are currently available. The result is that the vast majority of pediatric patients with severe heart failure are currently managed with paracorporeal VADs (i.e. pumps sitting outside the body), which in general are associated with higher risk profiles and require hospital management.
"The very favorable results of this study will be submitted to the U.S. Food and Drug Administration for determination of its suitability to initiate a clinical trial called the PumpKIN (Pump for Kids, Infants, and Neonates) Trial. We are hoping the trial will begin late this year. This study will be an important milestone in the new era of pediatric heart failure management with implantable VADs," explained lead investigator Iki Adachi, MD, Texas Children's Hospital, Houston.
While there are VADs designed for adults, there are no implantable VADs specifically designed for small children. The current study aims to address this unmet need. The Infant Jarvik 2015 is an implantable axial-flow VAD. Compared to its predecessor the Infant Jarvik 2000, in vitro testing demonstrated that it offers significantly improved hemolysis profile, which is one of the most important challenges in development of small pumps.
The Infant Jarvik 2015 offers up to 3.0 liters per minute flow rate, which is approximately double the flow its predecessor can provide. This important difference in flow capability would suggest that the new pump could be used in wider range of children.
Advertisement
The most significant finding was very minimal hemolysis (premature destruction of red blood cells) despite high pump speed (the pump rotor spins up to 18,000 times per minutes). In six animals, there were small kidney infarcts, which is often seen in this type of animal studies in part due to inability to fully anticoagulate these animals. The entire VAD flow pathway was clean, without thrombi or fibrin deposits except in one.
Advertisement
Source-Newswise