Medindia LOGIN REGISTER
Medindia

New Kit to Detect COVID-19 Virus Effectively and Efficiently

by Kesavan K.E.T. on Aug 6 2022 6:43 PM
Listen to this article
0:00/0:00

At-home, saliva-based COVID-19 testing kit is as effective as PCR in preliminary analysis and the prototype delivers the results in 45 minutes.

New Kit to Detect COVID-19 Virus Effectively and Efficiently
Polymerase chain reaction (PCR) tests, also called molecular tests or nucleic acid tests, are considered the ’gold standard’ in detecting the presence of COVID-19 virus and its variants.
But the problem is that the test may take a few days to process, resulting in an unnecessary quarantine for negative individuals or delays for those who require proof of negative testing for traveling to other countries. Rapid antigen-detecting tests are convenient, but are less reliable than PCR tests.

So an at-home, saliva-based testing platform has been developed that can provide the results in 45 minutes or less, developed by Penn State researchers to bridge the gap between accuracy and convenience. In preliminary tests, the platform detected the COVID-19 virus with the same level of sensitivity as PCR tests. Results of this research were published in ACS Sensors.

“PCR test results take about an hour to develop in a lab, but you have to factor in the time it takes to send the sample to a lab and for the lab to process it,” said Principal Investigator Weihua Guan, associate professor of electrical engineering and of biomedical engineering in Penn State’s College of Engineering. “We wanted to create a viable alternative to the PCR for people to use at home, without having to endure the invasive nasal test.”

Research to Achieve a Time-Saving Kit

A palm-sized testing kit, where an individual spits into a cartridge and inserts it into a processing platform, was developed and achieved by Guan and his team. Within 45 minutes, test results are sent to a custom android app developed by the researchers.

The platform uses reverse transcription loop-mediated isothermal amplification, or RT-LAMP, to detect the virus. The testing device first heats the saliva to 203 ℃F, the temperature at which viral particle shells break apart and release their genetic material. The genetic material is then mixed with pre-packaged reagents in a microfluidic cartridge.

Finally, the sample is cooled to 149 ℃F, triggering another chemical reaction in which a few viral molecules are multiplied into billions of copies, making the virus easier to identify. If the virus is present in the saliva sample, the user will receive a positive result on their connected smartphone app.

To test the setup, Guan and his team infused human saliva samples purchased commercially with inactivated COVID-19 virus particles and ran the samples through the prototype. They also tested a couple of clinical specimens. The platform accurately determined whether every sample was positive or negative for the virus.

Advertisement
“We tested hundreds of mock samples and controlled the quantity of COVID-19 particles in each one,” Guan said. “Our platform proved to be highly sensitive to the presence of the virus in both the mock and clinical samples, with the standards set by the PCR test as our benchmark.”

The researchers said that they plan to continue testing their platform with more clinical COVID-19 samples through a collaboration with Yusheng Zhu, medical director of the Clinical Chemistry and Automated Testing Laboratory at the Penn State Milton S. Hershey Medical Center.

Advertisement
In addition to more clinical testing, the researchers also are working to improve the test’s short shelf life, as the enzymes in the prototype degrade at room temperature within three days of production. The team is experimenting with reagent lyophilization, a method of freeze-drying biological material that can extend enzyme shelf life. According to Guan, preliminary results indicate the method will allow the RT-LAMP test to last at least six months at room temperature in stores or in the medicine cabinet at home.

The researchers filed a provisional patent application on their device and said they plan to commercialize it, pending scaled-up clinical testing and review by the U.S. Food and Drug Administration.

Suresh V. Kuchipudi, interim director of Penn State’s Animal Diagnostic Laboratory (ADL) and Dorothy Foehr Huck and J. Lloyd Huck Chair in Emerging Infectious Diseases, and Michele Yon, research technologist with ADL, acquired the clinical samples tested in this work. Other contributors include Zifan Tang, Aneesh Kshirsagar and Tianyi Liu, all Penn State doctoral students in electrical engineering, and Jiarui Cui, a Penn State undergraduate student in electrical engineering.

Source-Eurekalert


Advertisement